When building for the future, energy efficiency and a reduced carbon footprint are at the forefront of building design. Passivhaus is a building standard focused on creating low-energy buildings, designed carefully to consider how energy is used and lost. From residential buildings to commercial projects, Passivhaus allows homes, workplaces, and more to maintain a stable indoor temperature with minimal reliance on conventional heating and cooling.
By following its five key principles, Passivhaus is the answer to a more comfortable, eco-friendly future of buildings. In this article, we’ll explore Passivhaus in detail and why architects utilise this building standard in many of our sustainable designs.
Developed in Germany, Passivhaus, which is German for ‘passive house’, refers to a standard of buildings designed and constructed with a significant focus on superior energy efficiency and comfort, as well as affordability. It is a voluntary energy-based building standard, and one which is becoming more and more popular in the creation of new structures. It is possible to make these same changes to existing structures, but this retrofitting to Passivhaus standards is known as EnerPHit, not Passivhaus.
Any new building can be designed to meet Passivhaus standards. It is achieved by ensuring a high-performance building envelope – this is essentially the ‘skin’ of the building. The envelope is the physical barrier between the interior of the building and the exterior environment, including the roof, external walls, windows, doors, floors, and other components that ‘envelope’ the interior.
This high-performance building standard is reached successfully by looking at insulation, airtightness, and heat recovery ventilation, helping it consume up to 90% less energy via heating and cooling. These elements fall under the five key principles of Passivhaus, essential for buildings to meet its strict and incredibly worthwhile standards.
These fundamental and connected design principles ensure a building’s complete energy efficiency when utilised in harmony with each other.
In your typical building, such as a school or home, heat gets lost as it moves. This is often through the building envelope via conduction and convection.
Conduction: the transfer of heat through solid materials (loss through walls, roofs, and other envelope elements).
Convection: the transfer of heat through the air (loss through cracks and gaps, such as floorboards or ill-fitted windows).
In cooler climates like ours in the UK, you’ll commonly find internal heating systems rather than cooling. When a building is poorly insulated, such as in old homes, money ends up wasted on heating the air, only for it to escape through mediocre insulation via conduction.
With a Passive House, thick and continuous high-performance insulation materials are used throughout the building’s envelope. By ensuring the insulation is continuous, architects can design to eliminate the chance of heat escaping through gaps such as wall-to-roof junctions, where gaps often exist. By keeping the heat in, homes stay warmer for significantly longer without needing to turn the heating on. Fortunately, insulation has the ability to keep just as much heat out as in – it acts as a thermal block, preventing the transfer of heat into the building, just as it does with cold temperatures.
At Wincer Kievenaar, we carefully select the appropriate insulation materials for the build while maintaining our commitment to sustainability. In walls and roofs, we often opt for blown insulation such as high-performance cellulose fibres made from recycled newspapers. For insulation below the slab, plastic-based extruded polystyrene is highly effective, or, for a more sustainable alternative, we choose foam glass, formed of up to 99% recycled glass.
As we’ve mentioned, heat transfer can occur via convection, meaning the loss of heat through the air. Opportunities for this to happen can be found anywhere in conventional buildings, from poorly sealed windows, loose floorboards, gaps under doors, and anywhere else that can act as an exit point for air. This loss of heat means more effort is required to warm up the building, increasing heating bills, while also decreasing the thermal comfort levels of inhabitants or users.
Airtightness is incredibly important in passive housing. Buildings aiming to meet Passivhaus standards should have no more than 0.6 air changes per hour at 50 pascals. This means that no more than 60% of a building’s total air volume should escape and be replaced within one hour, under test conditions. A pascal (Pa) is a unit of pressure. In Passivhaus testing, 50 pascals is the pressure used, which is much stronger than the normal wind pressure you’d find inside a house. This performance metric is essential in Passivhaus building certification.
When a building is properly designed, well-insulated, and constructed to ensure extreme airtightness, it retains a significant amount of heat, resulting in superior thermal control.
A thermal bridge, sometimes referred to as a cold bridge, is an area or weak component that acts as a bridge between the interior and exterior of a building for heat to escape. These bridges are typically made of good heat conductors and are mostly found in insulation gaps and building junctions. There are several categories that thermal bridges can be split into:
Point thermal bridges: Heat loss via a single point, such as isolated beams, structural fasteners, and steel balconies.
Linear thermal bridges: Heat loss along a line or edge, often at the meeting point of two building elements, such as roof-to-wall junctions.
Geometrical thermal bridges: Heat loss via a building’s shape or layout, such as corners and edges.
Repeating thermal bridges: Heat loss via regular, evenly distributed repeating points, such as wall studs and ties.
Architects well-practised in Passive House design are able to utilise many methods in energy efficiency to eliminate or greatly reduce these weak points to Passivhaus standards. This includes designing and detailing junctions carefully to avoid direct heat paths, using thermal break components in structural connections, minimising unnecessary penetrations, considering all materials carefully, and, of course, keeping insulation continuous wherever possible.
It’s commonly viewed that windows are the biggest source of heat loss in a building. It cannot be helped that they are weak spots – their role is to allow light and visibility, and therefore cannot be insulated like other materials. Because of this, Passivhaus buildings require extremely high standards be met for exterior-facing glass.
Triple-glazing systems are used for all glass within the building’s envelope, and architects also rely heavily on the strategic placement of windows and glass doors. Passive solar gains are highly utilised in Passivhaus design, as it’s an excellent way to introduce heat into the building naturally. Windows and glass features will be placed to take advantage of sunlight in colder seasons, and unnecessary extra windows are avoided to reduce the risk of heat loss.
Expert architectural consideration sees windows placed where shading components are present, such as overhangs and trees, to reduce overheating during warmer seasons. Frame materials and insulation are chosen carefully to avoid too much heat conduction, and proper installation and sealing are prioritised to ensure airtightness.
Another key principle that sets Passive Houses apart from conventional buildings is the use of mechanical ventilation systems, or Heat Recovery Ventilators (HRVs). These cleverly designed whole-house systems deliver occupants a continuous supply of fresh, filtered air, while recovering heat from the air it’s extracting from the building. This is possible thanks to a heat exchanger within the ventilation system, which transfers the heat from the warm outgoing air to the cool air coming in from the outside. It does all of this while keeping the ingoing and outgoing streams from crossing. During warmer seasons, the heat exchanger can be bypassed to not transfer heat, allowing cool, unwarmed air to enter the building.
This method of ventilation is crucial in Passive Housing as these buildings are airtight – without ventilation, no air is moving in or out of the building, resulting in stale and moist indoor spaces. A mechanical ventilation system is needed to get rid of pollutants, moisture, smells, and even CO2, to ensure the comfort and safety of the building’s occupants, and to prevent damage to the building itself.
At least 75% of heat must be recovered from outgoing air within a heat recovery system for a Passivhaus to be certified. HRVs are often fitted with performance filters to remove dust and pollen from the air, enhancing comfort even further. Advanced systems are utilised for buildings where ventilation requirements may differ from room to room, improving cost efficiency even further.
Adopting Passivhaus standards transforms the way we think about energy in buildings. From reducing energy consumption to creating exceptionally comfortable interiors, these low-energy buildings prove that sustainability doesn’t mean compromising on comfort.
If you’re interested in exploring Passivhaus for your building project, don’t hesitate to get in touch. We have Passivhaus experts on our team who are highly experienced in designing low-energy homes, schools, and more.
Ensuring buildings meet Passivhaus standards involves a vast amount of data. We measure and input this to calculate modelling, thermal bridging, and more detailing, allowing us to deliver clients accurate information and a clear roadmap from the beginning.
We are committed to designing spaces that are both environmentally responsible and truly enjoyable to live in. As more people embrace Passivhaus, we move closer to a bright future where energy-efficient buildings are the standard, not the exception.
Connor first joined us in September 2017 while studying Building Surveying at Anglia Ruskin University. Read more
As we move toward a net-zero future in the UK, we must carefully consider how we design and construct our buildings. Read more